LCD and 16-Zone LED Keypads
1689 1641
16-Zone LED Keypad LCD Keypad
User’s Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 46 47

Shrnutí obsahu

Strany 1 - User’s Manual

LCD and 16-Zone LED Keypads1689 164116-Zone LED Keypad LCD KeypadUser’s Manual

Strany 2 - TABLE OF CONTENTS

Spectra Keypads 92.6 TROUBLE DISPLAY Your alarm system continuously monitors fourteen possibletrouble conditions. Most of these trouble conditions can

Strany 3 - 2 User’s Manual

10 User’s ManualFor Spectra 1641 LCD Keypad: When atrouble condition occurs, “System Trouble[TRBL] to View” will appear on the screen. Trouble Lis

Strany 4 - 1.0 INTRODUCTION

Spectra Keypads 11[3] Power Failure The system has detected a loss of AC power. This troubleusually occurs during a power failure. If a power failure

Strany 5 - 2.0 BASIC OPERATION

12 User’s Manual[8] Timer Loss Your alarm system’s clock must be re-programmed. This isthe only trouble that we recommend that you correct. [9] Tamper

Strany 6 - 2.2 VISUAL FEEDBACK

Spectra Keypads 13[13] Wireless Transmitter Supervision Loss A wireless transmitter is no longer communicating with itsreceiver or its batteries are d

Strany 7 - 2.3 AUDITORY FEEDBACK

14 User’s Manual3.0 PROGRAMMING ACCESS CODESAccess Codes are personal identification numbers that allowyou to enter certain programming modes, arm or

Strany 8 - 2.4 ALARM MEMORY DISPLAY

Spectra Keypads 15User Access Codes (see section 3.4) that are assigned to thesame partition. Master Codes cannot modify or delete User AccessCodes as

Strany 9 - CLEAR] twice to exit

16 User’s ManualFor Spectra 1689 LED Keypad also refer to Appendix A.Table 1: User Code SectionsHow Do I Program Access Codes?1) Press [ENTER]2) Enter

Strany 10 - 2.6 TROUBLE DISPLAY

Spectra Keypads 174.0 ARMING & DISARMINGTake full advantage of your Spectra system by familiarizingyourself with all the arming methods. If your s

Strany 11 - Trouble List

18 User’s Manual4.3 REGULAR ARMINGThis method will arm all the zones in the selected partition. Please note that Regular Arming can also be activated

Strany 12 - Spectra Keypads 11

Spectra Keypads 1TABLE OF CONTENTS1.0 INTRODUCTION ...32.0 BASIC OPERATION ...

Strany 13 - 12 User’s Manual

Spectra Keypads 194.4 STAY ARMINGThis method allows you to remain in the protected area whilepartially arming the system. Stay Zones are zones that ar

Strany 14 - 2.7 PARTITIONING

20 User’s Manual4.4.1 Instant ArmingAfter Stay Arming the system and during its Exit Delay,press and hold the [STAY] button for 3 seconds. You should

Strany 15 - 3.0 PROGRAMMING ACCESS CODES

Spectra Keypads 214.5 FORCE ARMINGForce Arming allows you to rapidly arm the system withoutwaiting for all zones in the system to close. During Force

Strany 16 - 3.3 DURESS CODE

22 User’s Manual4.6 MANUAL BYPASS PROGRAMMINGManual Bypass Programming allows you to program thealarm system to ignore (deactivate) specified zones th

Strany 17 - 16 User’s Manual

Spectra Keypads 23For Spectra 1641 LCD Keypad: When zonesare bypassed, “Zone(s) Bypassed [BYP] toView” will appear on the screen. To remove the Byp

Strany 18 - 4.0 ARMING & DISARMING

24 User’s Manual4.7 ONE-TOUCH ARMINGOne-Touch Arming allows you to arm the system withoutusing an access code. 4.7.3 One-Touch Regular ArmingPress and

Strany 19 - 4.3 REGULAR ARMING

Spectra Keypads 25Exit and Stay Arm: Press and hold the [STAY] button for 3seconds (see Note1, p.23) to start the Exit Delay (seesection 4.1). When t

Strany 20 - 4.4 STAY ARMING

26 User’s Manual4.8 KEYSWITCH ARMINGA keyswitch can be used to arm and disarm the system. Akeyswitch is programmed to Stay Arm (see section 4.4) orRe

Strany 21 - 20 User’s Manual

Spectra Keypads 27For Spectra 1689 LED Keypad also refer to Appendix A.A 60-second Exit Delay (see section 4.1) will startbefore the system arms. At t

Strany 22 - 4.5 FORCE ARMING

28 User’s Manual5.0 ADDITIONAL FEATURESEach keypad must be Chimed and Muted separately.Chime Zones and Keypad Muting must be re-programmed if your sys

Strany 23 - 4.6 MANUAL BYPASS PROGRAMMING

2 User’s Manual5.0 ADDITIONAL FEATURES ... 285.1 Programming Chime Zones ... 2

Strany 24 - (see Note 1)

Spectra Keypads 29For Spectra 1641 LCD Keypad: To remove the Chime feature from a zone, in Step 3 re-enterthe two-digit zone number of the desired zo

Strany 25 - 4.7 ONE-TOUCH ARMING

30 User’s Manual5.3 PANIC ALARMSIn case of emergency, the Spectra system can provide threepanic alarms that can immediately generate an alarm aftersim

Strany 26 - FORCE] button for 3

Spectra Keypads 315.5 PGM BUTTON (PROGRAMMABLE OUTPUTS) Your Spectra system may include one or moreprogrammable outputs (PGMs). When a specific event

Strany 27 - 4.9 AUTO-ARMING

32 User’s Manual5.6.4 Cancel Communication[ENTER] + [MASTER CODE] + [STAY]Cancels all communication with the Winload software if it hasbeen initiated.

Strany 28 - MASTER CODE]

Spectra Keypads 336.0 FIRE ALARMSUpon a fire alarm, the bell/siren will emit three “squawks” at 2second intervals until silenced or reset by entering

Strany 29 - 5.0 ADDITIONAL FEATURES

34 User’s ManualFigure 6.1: Delayed Fire Zone Event SequenceDelayed Fire Zoneis triggeredBell/siren activated. Transmission ofthe report delayed for 3

Strany 30 - 5.2 KEYPAD MUTING

Spectra Keypads 35Minimizing Fire HazardsThe three most common causes of fires:• Cooking is the leading cause of home fires in the U.S. It'salso

Strany 31 - [TIME]

36 User’s ManualProviding a Fire Warning SystemHousehold fires are especially dangerous at night. Firesproduce smoke and deadly gases that can overcom

Strany 32 - 5.6 QUICK FUNCTION KEYS

Spectra Keypads 377.0 TESTING & MAINTENANCEWith the system disarmed and the “READY” Light on, activatemotion detectors by walking in the protected

Strany 33 - CLEAR] to exit

38 User’s Manual8.0 SYSTEM CHECKLISTZone DescriptionIs this system partitioned? Yes l No lPartition 1 =_______________________________________

Strany 34 - 6.0 FIRE ALARMS

Spectra Keypads 31.0 INTRODUCTIONThank you for selecting the Spectra Security System fromParadox Security Systems. The Spectra Security Systemwill giv

Strany 35 - 34 User’s Manual

Spectra Keypads 39Access CodesFor security reasons, write only the user’s name and not hisor her access code. 4-Digit Codes l 6-Digit Codes l10:

Strany 36 - Spectra Keypads 35

40 User’s Manual006:_________________l l l l l007:_________________l l l l l008:_________________l l l l l009:_________________l l l l l010:__________

Strany 37 - 36 User’s Manual

Spectra Keypads 41026:_________________l l l l l027:_________________l l l l l028:_________________l l l l l029:_________________l l l l l030:________

Strany 38 - 7.0 TESTING & MAINTENANCE

42 User’s ManualSpecial Buttons and Featuresl [ENTER] One-touch Regular Arming is activatedl [STAY] One-touch Stay Arming is activatedl [FORCE] One-to

Strany 39 - 8.0 SYSTEM CHECKLIST

Spectra Keypads 43System TimersEnter and exit your premises through the designated doors. Exit Delay 1 (Partition 1): _______sec. = time to exit site

Strany 40 - Spectra Keypads 39

44 User’s Manual9.0 APPENDIX AFor Spectra 1689 LED Keypad onlyDo not read the following if you have not readthese sections: •User Access Codes (see se

Strany 41 - 40 User’s Manual

WarrantyThe Seller warrants its products to be free from defects inmaterials and workmanship under normal use for a period ofone year. Except as speci

Strany 43 - 42 User’s Manual

4 User’s Manual2.0 BASIC OPERATIONThe Spectra 1689 LED and 1641 LCD Keypads function inthe same way, but display the visual feedback differently.This

Strany 44 - Spectra Keypads 43

Spectra Keypads 52.2 VISUAL FEEDBACK2.2.1 For the Spectra 1689 LED Keypad The numbers and symbols on the keypad’s screencommunicate your system’s stat

Strany 45 - 9.0 APPENDIX A

6 User’s Manual2.2.2 For the Spectra 1641 LCD KeypadThe LCD (liquid crystal display) is a 32-character screen thatdisplays messages that can be custom

Strany 46

Spectra Keypads 72.4 ALARM MEMORY DISPLAYAll zones where alarms have occurred will be stored inmemory. The system will erase the contents of the Alarm

Strany 47

8 User’s Manual2.5 EVENT LIST (For Spectra 1641 LCD Keypad Only)The Event List will record all the actions that occur in thesystem. Each event that oc