48-Zone LED Keypad
User Manual
DGP2-648
Zobrazit stránku 0
1 2 3 4 5 6 ... 43 44

Shrnutí obsahu

Strany 1 - User Manual

48-Zone LED KeypadUser ManualDGP2-648

Strany 2

8 User’s ManualIn Area Status Display, the following will illuminate for the areaselected:• The area lights (A1, A2, A3, and A4) if the associated are

Strany 3 - TABLE OF CONTENTS

Digiplex 848/DigiplexNE LED Keypads 9n5.0 ARMINGWhen the system is armed, it will respond to any breach in the zonesaccording to the way each zone is

Strany 4 - 2 User’s Manual

10 User’s Manual5.3 STAY ARMINGStay Arming will partially arm your system to permit you to remain inthe protected area. For example, you can arm your

Strany 5 - 1.0 INTRODUCTION

Digiplex 848/DigiplexNE LED Keypads 11n5.5 FORCE ARMINGForce Arming allows you to arm your system when specific zones areopen. Your installer can prog

Strany 6 - 2.0 BASIC OPERATION

12 User’s ManualYou may use the One-Touch keys (see section 5.6) or akeyswitch (see section 5.7) to arm the area. Ask yourinstaller for details. 5.6 O

Strany 7 - 2.2 KEYPAD INDICATOR LIGHTS

Digiplex 848/DigiplexNE LED Keypads 13n5.7.2 MOMENTARY KEYSWITCHTo arm the system, place it in the “ON” position briefly then place itback in the “OFF

Strany 8 - 2.2.4 ILLUMINATION

14 User’s ManualIf you have access to more than one area, the symbol(s)corresponding to the area(s) for which you have access willilluminate in sequen

Strany 9 - 3.1 AREA DISPLAY

Digiplex 848/DigiplexNE LED Keypads 15nFire Zones cannot be bypassed. 5.9.1 BYPASS RECALLThe Bypass Recall feature enables you to bypass the same zon

Strany 10 - 4.1 ZONE DISPLAY

16 User’s Manual2) Press the [Byp] key. Your keypad will emit a Confirmation Beep and the PRG action light will illuminate. The BYP action light will

Strany 11 - 5.2 REGULAR ARMING

Digiplex 848/DigiplexNE LED Keypads 17n6.0 DISARMINGWhen the system is disarmed, the system deactivates the zones sothe alarm will not be triggered if

Strany 13 - 5.5 FORCE ARMING

18 User’s ManualIn case of a burglar alarm, leave the premises and callyour security company from a safe place.6.3 ALARM MEMORY DISPLAYYour system wil

Strany 14 - 5.7 KEYSWITCH ARMING

Digiplex 848/DigiplexNE LED Keypads 19n7.0 ACCESS CODESAccess Codes are codes that will allow you and others to access thesystem. These codes can be p

Strany 15 - 5.8 AUTO-ARMING

20 User’s Manual7.2 USER ACCESS CODESYour keypad is compatible with both the Digiplex 848 and DigiplexNEsystem. On a Digiplex 848 system, this keypad

Strany 16 - 5.9 BYPASS PROGRAMMING

Digiplex 848/DigiplexNE LED Keypads 21nHow do I program a user access code?1) Enter your [System Master Code] or [Access Code] with Master feature.2)

Strany 17 - 5.9.1 BYPASS RECALL

22 User’s ManualIf your keypad emits a Rejection Beep, you may have chosen anexisting User Code or the Master Code used to modify or create thecode do

Strany 18 - 16 User’s Manual

Digiplex 848/DigiplexNE LED Keypads 23nPress option ON/OFF Option Description[3] Duress FeatureOFF (default) Duress feature disabled.ON Duress feature

Strany 19 - 6.2 DISARMING AN ARMED SYSTEM

24 User’s Manual7.3 AREA ASSIGNMENTIn a partitioned system the system can be divided into distinctprotected areas. Programming access to a specific ar

Strany 20 - 6.3 ALARM MEMORY DISPLAY

Digiplex 848/DigiplexNE LED Keypads 25nTable 2: Area AssignmentIn Table 1 and Table 2 the User Code Option or Area isconsidered “ON” when the correspo

Strany 21 - 7.1 SYSTEM MASTER CODE

26 User’s Manual8.0 TROUBLE DISPLAYWhen your system experiences problems or is tampered with, theTRBL action light will illuminate. Most of the troubl

Strany 22 - 7.2 USER ACCESS CODES

Digiplex 848/DigiplexNE LED Keypads 27n8.0.1 GROUP [1]: SYSTEMTrouble [1]: AC FailureThis means that your system is running on the backup battery. The

Strany 23

Digiplex 848/DigiplexNE LED Keypads 1nTABLE OF CONTENTSINTRODUCTION... 3BASIC OPERATION...

Strany 24 - 22 User’s Manual

28 User’s Manualcleaned or a wireless device is no longer communicating with itsreceiver.8.0.5 GROUP [8]: CLOCK LOSS The time and date have been reset

Strany 25

Digiplex 848/DigiplexNE LED Keypads 29n9.0 ADDITIONAL FEATURES9.1 PROGRAMMABLE OUTPUTS (PGMS)Your system includes two or more programmable outputs (PG

Strany 26 - 7.3 AREA ASSIGNMENT

30 User’s Manualfor two seconds, the system will generate an alarm. The alarm canbe programmed to be either silent or audible according to yourprefere

Strany 27 - 7.5 KEYPAD LOCK-OUT

Digiplex 848/DigiplexNE LED Keypads 31n9.3.2 SETTING A CHIME ZONE TIME PERIODHow do I program all the keypad’s Chimed Zones to beep onlywhen they open

Strany 28 - 8.0 TROUBLE DISPLAY

32 User’s Manual9.4 PROGRAMMING THE TIMEHow do I program the time?1) Enter your [Access Code].2) Press the [TRBL] key.3) Press the [8] key.4) Enter th

Strany 29 - 8.0.4 GROUP [7]: ZONE FAULT

Digiplex 848/DigiplexNE LED Keypads 33n10.0 QUICK FUNCTION KEYSYou will only need to use the Quick Function keys upon your installeror security compan

Strany 30 - 8.0.5 GROUP [8]: CLOCK LOSS

34 User’s Manual11.0 FIRE AND BURGLAR ALARMS11.1 STANDARD FIRE ZONEDuring a fire alarm, the bell/siren will emit an intermittent sound(BEEP-BEEP-BEEP

Strany 31 - 9.2 PANIC ALARMS

Digiplex 848/DigiplexNE LED Keypads 35nFigure 2: Delayed Fire Zone

Strany 32 - 9.3 PROGRAMMING CHIME ZONES

36 User’s ManualThe Fire Zone may reset itself once the smoke hascleared. If it does not, simultaneously press and holdthe [Clear] and [Enter] keys fo

Strany 33

Digiplex 848/DigiplexNE LED Keypads 37n11.4 MINIMIZING HOME FIRE HAZARDSHow can you avoid the four most common causes of fires at home?1) Never leave

Strany 34 - 9.4 PROGRAMMING THE TIME

2 User’s ManualACCESS CODES... 19System Master Code... 19U

Strany 35 - 10.0 QUICK FUNCTION KEYS

38 User’s Manual12.0 TESTING AND MAINTENANCE12.1 BURGLAR ALARM TESTINGThis test requires two people. One person will watch the keypadwhile the other p

Strany 36 - 11.2 DELAYED FIRE ZONE

Digiplex 848/DigiplexNE LED Keypads 39nHow do I conduct the system test?1) Call the security company to advise them that you are testing the system.2)

Strany 37 - Figure 2: Delayed Fire Zone

40 User’s ManualWarrantyThe Seller warrants its products to be free from defects in materialsand workmanship under normal use for a period of one year

Strany 39 - 11.5 BURGLAR ALARM

780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADATel.: (450) 491-7444 Fax: (450) 491-2313www.paradox.c

Strany 40 - 12.4 SYSTEM TEST

Digiplex 848/DigiplexNE LED Keypads 3n1.0 INTRODUCTIONYour security system uses advanced technology which will provideyou with reliable security prote

Strany 41

4 User’s Manual2.0 BASIC OPERATIONThe system communicates by illuminating the “AC” light, the “Status”light and the various lights on the screen as sh

Strany 42 - 40 User’s Manual

Digiplex 848/DigiplexNE LED Keypads 5n2.1 AUDITORY FEEDBACK (BEEP TONES)When you enter information on your keypad, it will guide you withbeep tones to

Strany 43

6 User’s Manual2.2.2 CONFIDENTIAL MODEThe installer can program your keypad not to display the status ofyour system by changing the keypad from Normal

Strany 44

Digiplex 848/DigiplexNE LED Keypads 7n3.0 PARTITIONED SYSTEMYour installer can set your keypad to recognize separate protectedareas. A separated syste