Superbus Alphanumeric Touchpad
Page 5
Programming
The Superbus Alphanumeric Touchpad must be used
to program the panel. For a complete description of
programming commands, refer to the specific panel’s
Reference Manual or Installation Instructions. Refer to the
specific panel’s Owners Manual for operational
instructions.
Specifications
Compatibility: UltraGard
Power Requirements: 12 VDC, 75 mA (maximum)
Dimensions: 4.25” x 8.50” x 1.125” (H x W x D)
Notices
This equipment has been tested and found to comply with the limits for a class B device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment gen-
erates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communica-
tions. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
ν Reorient or relocate the receiving antenna on the radio or TV.
ν Increase the separation between the equipment and receiver.
ν Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
ν Consult the dealer or an experienced radio/TV technician for help.
ITI and CareTaker are registered trademark of Interactive Technologies, Inc. UltraGard is
a Trademark of Interactive Technologies, Inc.
HIM, or touchpad loop
reports trouble.
1. HIM, or touchpad unit
number is the same as
another bus device. Change
unit number on HIM,
HOM, and /or ESM, then
set panel to program mode
and back to RUN/NOR-
MAL.
2. Indicates a wiring problem.
Turn off or remove panel
power, check HIM and
touchpad wiring and cor-
rect where necessary.
3. Unit number on HIM or
touchpad was changed. Panel
must learn hardwire loops
again when HIM or touch-
pad unit number is
changed.
Panel reports trouble on
upper sensors 78 and 88.
1. ESM unit number is the
same as another bus device.
Change unit number on
ESM. Remove then restore
panel power, then set
panel to program mode
and back to RUN/NOR-
MAL.
2. Indicates a wiring problem.
Turn off the panel power
switch, check ESM wiring
and correct where neces-
sary.
Table 1. Troubleshooting (Continued)
Problem Cause/Action