SEKURE Paradox Esprit 616LED Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Bezpečnostní systémy pro řízení přístupu SEKURE Paradox Esprit 616LED. SEKURE Paradox Esprit 616LED User manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - User Manual

642 LCD KeypadUser Manual

Strany 2

8 User Manual3.0 Access CodesAccess codes are personal identification numbers that allowyou to enter certain programming modes and arm or disarmthe sy

Strany 3 - TABLE OF CONTENTS

Esprit+ 642 LCD Keypad 93.3 Programming Access CodesThe display will read: none to indicate that anaccess code is available (does not containinformati

Strany 4 - 2 User Manual

10 User Manual3.4 Deleting an Access CodeHow Do I Delete an Access Code?1) Press the [ENTER] key. The display will briefly read: enter code to program

Strany 5 - 1.0 Introduction

Esprit+ 642 LCD Keypad 114.0 Arming & DisarmingFor information on how to arm and disarm a partitionedsystem, please see “Partitioning the System”

Strany 6 - = to indicate a tip

12 User ManualPressing the [CLEAR] key will only erase the displaymessage and will not erase the memory contents.Arm or disarm to erase the memory con

Strany 7 - 2.0 Basic Operation

Esprit+ 642 LCD Keypad 134.5 Stay ArmingStay arming allows you to remain in the protected area whilepartially arming the system. You may choose to hav

Strany 8 - 2.3 Auditory Feedback

14 User Manual4.6 Fast ExitThis feature allows you to leave a perimeter that is alreadyarmed in Stay mode and have the system rearm itself. Youcan set

Strany 9 - 2.4 Info List

Esprit+ 642 LCD Keypad 154.8 Force ArmingForce arming enables you to rapidly arm the system withoutwaiting for all the zones in the system to close. F

Strany 10 - 3.0 Access Codes

16 User Manual4.9 Manual Bypass ArmingThis feature allows you to deactivate (ignore) specified zonesthe next time you arm the system. Once armed and t

Strany 11 - 3.3 Programming Access Codes

Esprit+ 642 LCD Keypad 174.11 One-Touch ArmingOne-Touch arming allows you to arm the system using asingle key without using an access code. These feat

Strany 13 - 4.0 Arming & Disarming

18 User Manual4.11.2 One-Touch Stay ArmingRefer to “Stay Arming” on page 13 for a full explanation of thisfeature.4.12 Keyswitch/Push-Button ArmingYou

Strany 14 - 4.4 Regular System Arming

Esprit+ 642 LCD Keypad 194.14 No Movement Automatic ArmingYour installer can program your panel to send a report and/orarm the system if the system is

Strany 15 - 4.5 Stay Arming

20 User Manualmode. To silence/reset a fire alarm, enter a valid accesscode. In case of fire follow your evacuation plan. If there is nofire condition

Strany 16 - 4.6 Fast Exit

Esprit+ 642 LCD Keypad 21succumbing to its hazardous effects. This may occur withintwo or three minutes upon detection of a fire. Advancewarning of a

Strany 17 - 4.8 Force Arming

22 User Manual5.0 Additional FeaturesSeveral keypad features can be programmed directly by you,without the help of an installer.5.1 Chime Zone Selecti

Strany 18 - 4.10 Bypass Recall

Esprit+ 642 LCD Keypad 23 5.3 Panic AlarmsIf you wish to signal a panic situation, your installer canprogram three panic zones on your keypad. You may

Strany 19 - 4.11 One-Touch Arming

24 User Manual5.4 Setting Time and DayHow Do I Use Panic Alarms?Press and hold both the [1] and [3] keys to generate apanic signal. The display will r

Strany 20 - 4.13 Timed Auto-Arming

Esprit+ 642 LCD Keypad 255.5 Quick Function KeysSeveral control panel features can be programmed quickly onthe keypad. The Security Company or install

Strany 21 - 4.15 Fire Alarms

26 User Manual5.6 Keypad SettingsYou can modify the keypad settings to suit your needs.[FORCE]Answer PC. The display will read: answer PC.This will in

Strany 22 - 20 User Manual

Esprit+ 642 LCD Keypad 275.7 Event ListYour control panel will create a buffer which contains a recordof all system activities including the time and

Strany 23 - Esprit+ 642 LCD Keypad 21

Esprit+ 642 LCD Keypad 1TABLE OF CONTENTSIntroduction ...3Legend ...

Strany 24 - 5.0 Additional Features

28 User Manualoccurred and what event occurred will scroll on the screen.As you press the [V] key, the next pair will scroll onto thescreen.Figure 5.1

Strany 25 - 5.3 Panic Alarms

Esprit+ 642 LCD Keypad 295.8.1 Arming a Partitioned SystemZones can be divided into two systems. Based on yourrequirements, the installer designates w

Strany 26 - 5.4 Setting Time and Day

30 User ManualIf your Access Code has access to System B:5.9 Disarming System A and B SeparatelyHow Do I Arm System A?1) Press the [STAY] key.2) Enter

Strany 27 - 5.5 Quick Function Keys

Esprit+ 642 LCD Keypad 31If your Access Code has access to System A:If your Access Code has access to System B:5.10 Testing & MaintenanceWe recomm

Strany 28 - 5.6 Keypad Settings

32 User ManualYour installer can advise you of the best way to test yourparticular system.5.10.1 Fire Alarm TestingDo not use flame or any kind of bur

Strany 29 - 5.7 Event List

Esprit+ 642 LCD Keypad 336.0 Trouble DisplayThe screen can display several trouble conditions. Whentrouble conditions occur, the display reads: system

Strany 30 - 5.8 Partitioning the System

34 User ManualPower FailureIf AC power is not being supplied to the control panel and/orthe power supply is unable to charge the battery. The LCDdispl

Strany 31 - Esprit+ 642 LCD Keypad 29

Esprit+ 642 LCD Keypad 357.0 System Check list7.1 Panic Buttons7.2 Zone ChecklistIs this a partitioned system? Yes NNo NSystem A =____________Syst

Strany 32 - How Do I Arm System B?

36 User ManualEntry Delay 1 is ________seconds.Entry Delay 2 is ________seconds.Exit Delay is ___________seconds.Zone # and DescriptionSystemA BZone

Strany 33 - How Do I Disarm System B?

Esprit+ 642 LCD Keypad 377.3 User Access Code ListUser Name System User Name System01: 16:02: 17:03: 18:04: 19:05: 20:06: 21:07: 22:08: 23:09: 24:10:

Strany 34 - How Do I Test the System?

2 User ManualOne-Touch Arming ...17Keyswitch/Push-Button Arming ...

Strany 35 - Trouble List

38 User ManualFor security reasons, write only user names, and notactual access codes.Other informationThis alarm system was installed on:____________

Strany 36 - 34 User Manual

Esprit+ 642 LCD Keypad 39WarrantyParadox Security Systems Ltd. (“Seller”) warrants its products to be free fromdefects in materials and workmanship un

Strany 37 - 7.0 System Check list

Notes_________________________________________________________________________________________________________________________________________________

Strany 39 - 7.3 User Access Code List

780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CanadaTel.: (450) 491-7444 Fax: (450) 491-2313www.paradox.ca

Strany 40 - Other information

Esprit+ 642 LCD Keypad 31.0 IntroductionThank you for selecting the Esprit+ Security System fromParadox Security Systems. The Esprit+ line of security

Strany 41 - Warranty

4 User Manual= to indicate a tip.= to indicate a button on the keypad.[KEY]

Strany 42

Esprit+ 642 LCD Keypad 52.0 Basic OperationMany of the features in your system must be enabled by yourinstaller. If the feature is not programmed, the

Strany 43

6 User ManualWhen zone status is normal, the LCD display will read:system ready. If any zones are open, the display willread: zones open. While the di

Strany 44

Esprit+ 642 LCD Keypad 7the system switches to a new status/mode, the keypadsounder will produce an intermittent beep tone (four shortbeeps).• Rejecti