Digiplex DGP-NE96 - 48 - Programming Guide
Power Unit Consumption Table
STEP 1: Using Table 1, calculate the total number of power units (PU) required by each device, module, and accessory in the system. Please take into
account devices connected to the control panel’s PGM outputs. Since the
BELL output has its own power supply, do not include the sirens
connected to it in the calculation.
STEP 2: If the Grand Total is less than 700PU, go to step 3. If the value is greater, you will require an external power supply (see External Power Supply
Connections drawing on page 46) to provide the additional power needed. Proceed with step 3 and refer to the example (Sample Power
Requirement Calculations drawing) on page 46.
STEP 3: Due to the degradation of a power signal over long distances (if this were the case, we recommend connecting a Paradox Power Supply
Module, DGP2-PS17), EACH length or run of wire in the system can support only a specific number of power units (PU). Using Table 2,
determine how many power units each length of wire can support. Please note that the total number of power units (PU) can never surpass
700PU.
Table 1: Power Unit Consumption Table
Description QTY. PU used by each Total PU
Grafica Graphic LCD Keypad (DNE-K07):
_______
X 150PU =
__________ PU
LCD Keypad (DGP2-641):
_______
X 80PU =
__________ PU
LED Keypad (DGP2-648):
_______
X 115PU =
__________ PU
Addressable Detectors (DG85, DGP2-50/60/70):
_______
X 30PU =
__________ PU
Addressable Door Contact (DGP2-ZC1):
_______
X 30PU =
__________ PU
1-Zone Hardwire Expansion Module (DGP2-ZX1):
_______
X 14PU =
__________ PU
4-Zone Hardwire Module (APR3-ZX4):
_______
X 28PU =
__________ PU
8-Zone Hardwire Module (APR3-ZX8):
_______
X 28PU =
__________ PU
Wireless Module (OMN-RCV3):
_______
X 50PU =
__________ PU
1-PGM Output Module (APR3-PGM1):
_______
X 28PU =
__________ PU
4-PGM Output Module (APR3-PGM4):
_______
X 150PU =
__________ PU
Printer Module (APR3-PRT1):
_______
X 40PU =
__________ PU
DVACS Module (DGP2-DVAC):
_______
X 40PU =
__________ PU
Annunciator Module (DGP2-ANC1):
_______
X 105PU =
__________ PU
InTouch Voice-Assisted Arm/Disarm Module (APR3-ADM2):
_______
X 105PU =
__________ PU
Access Control Module (DGP2-ACM1P):
Note: The DGP2-ACM1P consumes 165PU from its own power supply.
_______
X 165PU =
__________ PU
Maximum available power units = 700PU GRAND TOTAL
__________ PU
Table 2: Power Unit (PU) Limitations For Each Run of Wire
Gauge: 18AWG, Surface: 0.823mm
2
Gauge: 22AWG, Surface: 0.326mm
2
Gauge: 24AWG, Surface: 0.205mm
2
Length of each
run of wire
Available Power
Units (PU)
Length of each
run of wire
Available Power
Units (PU)
Length of each
run of wire
Available Power
Units (PU)
100ft. (30m) 700 100ft. (30m) 700 100ft. (30m) 700
200ft. (61m) 700 200ft. (61m) 682 200ft. (61m) 429
300ft. (91m) 700 300ft. (91m) 454 300ft. (91m) 286
400ft. (122m) 700 400ft. (122m) 341 400ft. (122m) 214
500ft. (152m) 690 500ft. (152m) 273 500ft. (152m) 171
600ft. (183m) 575 600ft. (183m) 227 600ft. (183m) 143
700ft. (213m) 493 700ft. (213m) 195
800ft. (244m) 431 800ft. (244m) 170
900ft. (274m) 383 900ft. (274m) 151
1000ft. (305m) 345 1000ft. (305m) 136
1500ft. (457m) 230
2000ft. (610m) 172
2500ft. (762m) 138
3000ft. (914m) 115