NVH 203
4.0 NVH DISPLAYS
When using the Vibration and Noise modes, the Tester offers a variety of ways to display
real time and stored data. A brief description of each display mode is listed below. A
complete description of operating each display mode is on the following pages.
TWO-DIMENSIONAL (2-D) SPECTRAL DISPLAY MODE
Frequency bands of 62.5 hz, 125 hz, 250 hz, and 500 hz are available for viewing real time
spectral Vibration or Noise data. Vibration component identifiers for the engine, driveline,
or wheel frequencies are displayed on the screen. A moveable cursor identifies the
magnitude and frequency of the vibration that is present at the current cursor position.
THREE-DIMENSIONAL (3-D) BARCHART DISPLAY MODE
Vibration or Noise data are displayed in bars that reflect the engine, driveline, wheel, and
total energy sampled. Eleven continuous cycles are displayed for analysis. The most
recent is displayed at the bottom of the Barchart display. Frequency bands of 62.5 hz, 125
hz, 250 hz, and 500 hz are available for viewing real time spectral Vibration or Noise data.
THREE-DIMENSIONAL (3-D) RASTER DISPLAY MODE
Eleven cycles of Vibration or Noise data are displayed in a 3-D format. The most current
cycle is located at the bottom of the 3-D display. Frequency bands of 62.5 hz, 125 hz, 250
hz, and 500 hz are available for viewing real time spectral Vibration or Noise data.
Vibration component identifiers for the engine, driveline, or wheel frequencies are
displayed on the screen.
PAUSE MODE
In the PAUSE mode you may cycle through the 2-D and 3-D display modes. In the 2-D
and 3-D spectral displays, vibration component, identifiers for engine, driveline, and
wheels are available. The amplitude range is also adjustable. Data can be saved in memory
for review at a later time; stored data is retained even when the Tester is powered down.