REFERENCE & INSTALLATION MANUAL
SPECTRA CONTROL PANELS V2.1
1728EX and 1728 1738EX and 1738
Zobrazit stránku 0
1 2 3 4 5 6 ... 59 60

Shrnutí obsahu

Strany 1 - SPECTRA CONTROL PANELS V2.1

REFERENCE & INSTALLATION MANUALSPECTRA CONTROL PANELS V2.11728EX and 1728 1738EX and 1738

Strany 2

8 REFERENCE & INSTALLATION MANUAL 2.9 SINGLE ZONE INPUTSDetection devices such as motion detectors and door contacts are connected to the cont

Strany 3 - TABLE OF CONTENTS

SPECT RA SERIES 92.11 KEYPAD AND KEYPAD ZONE CONNECTIONSTo connect the keypads to the control panel, remove the back cover and wire the GRN, YEL, RE

Strany 4 - LIST OF TABLES

10 REFERENCE & INSTALLATION MANUAL 2.13 FIRE CIRCUITSWhen a zone is program med as a Fire zone, the zone becomes normally open andrequi res an

Strany 5 - PART 1: INTRODUCTION

SPECTRA SERIES 11 3.2.2 FEATURE SELECT PROGRAMMING MET HO DAfter entering sections [001] to [016], [126] to [138], and [302] to [348], each option

Strany 6 - PART 2: INSTALLATION

12 REFERENCE & INSTALLATION MANUAL 3.3 CONFIGURING THE LED KEYPADSDepending on the version of the keypad, two methods can be used to configure

Strany 7 - 2.2 EARTH GROUND

SPECTRA SERIES 13J2 - EOL Definition JumperJumper J2 determines the keypad zone’s EOL defini tion. When the jumper is OFF, EOL is disabled and theke

Strany 8 - 2.6 TELEPHONE LINE CONNECTION

14 REFERENCE & INSTALLATION MANUAL 4.1 ACCESS CODE LENGTHSection [127 ]: System OptionsOption [2] OFF = 6-Digit Access Codes Option [2] ON = 4

Strany 9 - 2.7 BELL OUTPUT CONNECTION

SPECTRA SERIES 154.4.3 BYPASS PROGRAMMINGSections [302] to [348]: User Codes 002 to 048Option [3] OFF = Bypass Programming Disabled Option [3] ON =

Strany 10 - 2.9 SINGLE ZONE INPUTS

16 REFERENCE & INSTALLATION MANUAL PART 5: ZONE PROGRAMMINGThe Spectra control panel’s zone assignment depends on where the detection devi ces

Strany 11 - 2.12 KEYSWITCH CONNECTIONS

SPECTRA SERIES 175.3 REASSIGN ZONES TO EXPANSION INPUTS (1728EX & 1728 ONLY)Section [126 ]: General Op tion sOption [8] OFF = Reassign Zones to

Strany 13 - SPECTRA SERIES 11

18 REFERENCE & INSTALLATION MANUAL Figure 5.1: Spectra Zone Pro gramming5.5 ZONE DEFINITIONSAs demonstrated in Figure 5.1, sections [001] to

Strany 14

SPECTRA SERIES 195.5.2 ENTRY DELAY 2Sections [001] to [016]: Zones 1 to 16, First Digit = 2Entry Delay 2 zones are identical to the Entry Delay 1 zo

Strany 15 - PART 4: ACCESS CODES

20 REFERENCE & INSTALLATION MANUAL 5.6.2 STA NDA RD 24HR. FIR E ZONE1728/EX: Sections [001] to [005]: Zones 1 to 5, First Digit = 81738/EX:

Strany 16 - 4.4 USER CODE OPTIONS

SPECTRA SERIES 215.8.1 AUT O ZONE SHUTD OWNSections [001] to [016] = Zones 1 to 16Option [1] OFF = Auto Zone Shutdown Disabled Option [1] ON = Aut

Strany 17 - 4.5 LOCK MASTER CODE

22 REFERENCE & INSTALLATION MANUAL 5.8.6 DELAY BEFORE ALAR M REPORT CODE TRANSMISSION Sections [001] to [016]: Zones 1 to 16Option [7] OFF = D

Strany 18 - PART 5: ZONE PROGRAMMING

SPECTRA SERIES 23Enabling the ATZ feature allows you to install two detection devices per zone input terminal. Each detection devicewill have its ow

Strany 19 - 5.4 ZONE PROGRAMMING

24 REFERENCE & INSTALLATION MANUAL 6.3 REGULAR ARMING SWITCHES TO FORCE ARMINGSection [131 ]: Arming/Disar min g OptionsOption [2] OFF = Regul

Strany 20 - 5.5 ZONE DEFINITIONS

SPECTRA SERIES 25be bypassed regardless of their definition (except 24hr. zones). Upon arming, the control panel will transmit the NoMovement report

Strany 21

26 REFERENCE & INSTALLATION MANUAL 6.12 BELL SQUAWK ON ARM/DISARM WITH REMOTE CONTROLSection [131 ]: Arming/Disar min g OptionsOption [3] OFF

Strany 22 - 5.8 ZONE OPTIONS

SPECTRA SERIES 277.3 TAMPER RECOGNITION Section [1 32 ]: Zone Option s[1] OFF / [2] OF F: Tamp er R ecogn ition Disab led (defau lt)If the system i

Strany 23

SPECT RA SERIES 1TABLE OF CONTENTSIntroduction ... ... .. 3Features...

Strany 24 - 5.10 EOL ZONES

28 REFERENCE & INSTALLATION MANUAL Silent alarm:The control panel emits a Confirmation Beep and transmits the appropriate Panic report code if

Strany 25 - 6.2 STAY ARMING WITH DELAY

SPECTRA SERIES 29PART 8: REPORTING AND DIALER SETTINGSThe following section explains all the features and options that must be programmed in order f

Strany 26 - 6.6.1 AUT O-ARM TIMER

30 REFERENCE & INSTALLATION MANUAL 8.1 REPORTING/DIALER (ENABLE/DISABLE)Section [135 ]: Dialer OptionsOption [3] OFF = Reporting/Dialer Disab

Strany 27 - 6.10 EXIT DELAY

SPECTRA SERIES 31page 24). Only reports if Disarming Reporting Options (see page 36) are set to always r epor t disarming. • REM O TE D ISARM : S

Strany 28 - PART 7: ALARM OPTIONS

32 REFERENCE & INSTALLATION MANUAL be delayed (see Pow er Failure Report D elay on page 36).• BATTER Y FA IL URE: backup battery is disconnec

Strany 29 - 7.4 KEYPAD PANIC OPTIONS

SPECTRA SERIES 338.4 PARTITION ACCOUNT NUMBERSSection [143] = Partition 1, [144] = Partition 2All report codes are preceded by a 4-digit or 3-digit

Strany 30 - 7.5 PANIC LOCKOUT TIMER

34 REFERENCE & INSTALLATION MANUAL 8.5.4 CONTACT ID OPTIONSSection [136]: Dialer OptionsOption [3] OFF = Programmable Codes Option [3] ON =

Strany 31 - SPECTRA SERIES 29

SPECTRA SERIES 35backup telephone number after every fai led attempt. If no backup telephone number is programmed, the controlpanel will never repo

Strany 32 - 8.2 REPORT CODES

36 REFERENCE & INSTALLATION MANUAL 8.15 RECENT CLOSE DELAYSection [0 85 ] 000 to 255 seconds, Default = no delayIf after having armed the syst

Strany 33

SPECTRA SERIES 37[1] ON / [2] OF F: Alarm If System Armed Upon line test failure, a TLM Trouble will appear in the keypads’ Trouble Display (see pag

Strany 34 - Sections [211] to [213]

2 REFERENCE & INSTALLATION MANUAL Settings for WinLoad Software... 44Panel Answer Options ...

Strany 35 - 8.5 REPORTING FORMATS

38 REFERENCE & INSTALLATION MANUAL 9.2 PGM DEACTIVATION EVENTSections [121], [123], [125]After PGM activation, the PGM will return to its norm

Strany 36 - 8.7 EVENT CALL DIRECTION

SPECTRA SERIES 39PART 10: SYSTEM SETTINGS10.1 HARDWARE RESETPerforming a hardware reset will set all control panel settings to factory default excep

Strany 37 - SPECTRA SERIES 35

40 REFERENCE & INSTALLATION MANUAL 10.6 SYSTEM REAL-TIME CLOCK Section [2 80 ] Program the current time into section [280] using the 24-hour c

Strany 38

SPECTRA SERIES 4110.10 CONFIDENTIAL MODESection [126] Options [1], [2] and [3] Option [1] OFF = Confidential Mode Disabled (default)Option [1] ON =

Strany 39 - PART 9: PROGRAMMABLE OUTPUTS

42 REFERENCE & INSTALLATION MANUAL 10.13 PRINTER BUS MODULE SUPERVISIONSection [129 ]: General Op tion s Option [8] OFF = Printer Bus Module S

Strany 40

SPECTRA SERIES 43[7] OFF / [8] ON : Trouble OnlyWhen a tamper occurs on a wireless transmitter zone in a disarmed system, a Wireless Transmitter Sup

Strany 41 - PART 10: SYSTEM SETTINGS

44 REFERENCE & INSTALLATION MANUAL PAR T 11: SETTINGS FOR WINLOAD SOFTWARE11.1 PANEL ANSWER OPTIONSThe following two options define how the co

Strany 42 - 10.7 CLOCK ADJUST

SPECTRA SERIES 4511.5 CALL WINLOAD SOFTWARE[ENTER] + [INSTALLER CODE] + [BYP] The control panel will dial the PC Telephone Number programmed in sect

Strany 43

46 REFERENCE & INSTALLATION MANUAL PAR T 12: USER OPERATION12.1 TROUBLE DISPLAY The Spectra system continuously monitors fourteen possible tr

Strany 44

SPECTRA SERIES 4712.2 PROGRAMMING ACCESS CODESAccess Codes are personal identification numbers that all ow you to enter certai n pr ogramming modes,

Strany 45 - SPECTRA SERIES 43

SPECT RA SERIES 3PART 1: INTRODUCTION1.1 FEATURES• Up to 16 fully programmable zones• Two completely independent partitions. Many of the features an

Strany 46 - 11.4 PC TELEPHONE NUMBER

48 REFERENCE & INSTALLATION MANUAL 12.3 DISARMING & DEACTIVATING AN ALARM To disarm an already armed system or to deactivate an alarm, sim

Strany 47 - 11.8 CALL BACK WINLOAD

SPECTRA SERIES 4912.7 FORCE ARMINGForce Arming allows users to rapidly arm the system, without having to wait for all zones in the system to be clos

Strany 48 - PAR T 12: USER OPERATION

50 REFERENCE & INSTALLATION MANUAL One-Touch Regular ArmingPress and hold the [ENTER] key for 3 seconds* to arm all zones in the partition.One

Strany 49 - 12.2 PROGRAMMING ACCESS CODES

SPECTRA SERIES 51emits a confirmation beep, this means the chime feature has been enabled for that zone. If the keypad emits arejection beep, this m

Strany 50 - 12.6 INSTANT ARMING

52 REFERENCE & INSTALLATION MANUAL FCC WARNINGSIMPORTANT INFORMATIONThis eq uip me nt complies with Part 6 8 of the FCC rules su bpart D a nd

Strany 51 - 12.9 ONE-TOUCH ARMING

SPECTRA SERIES 53ATTACHMEN T L IMITATION NOTICEThe Industry Canada label identifies certified equipment. This certificationmean s tha t th e equ ipm

Strany 52 - 10-ZONE LED KEYPAD:

54 REFERENCE & INSTALLATION MANUAL INDEXNumerics24Hr. Buzzer Zone ...1924 Hr . De l ayed

Strany 53 - 12.15 KEYPAD MUTING

SPECTRA SERIES 55Ke ypad Backlig ht ...51Ke ypad In stallat ion ...

Strany 54 - FCC WARNINGS

56 REFERENCE & INSTALLATION MANUAL Wireless Bus Module Supervision ...42Wireless Transmitter Low Battery S

Strany 56

4 REFERENCE & INSTALLATION MANUAL PART 2: INSTALLATION2.1 LOCATION AND MOUNTINGBefore mounting the cabinet, push the five white nylon mounting

Strany 57 - SPECTRA SERIES 55

PRINTED IN CANADA 02/2003 17X8-EI07

Strany 58

SPECT RA SERIES 5Figure 2.2: Spectra 1728EX and 1728 Control Panel Overview2.2 EARTH GROUNDConnect the zone and dialer ground terminals from the co

Strany 59

6 REFERENCE & INSTALLATION MANUAL 2.3 AC POWERDo not use any switch-controlled outlets to power the transformer. Connect the transformer as sh

Strany 60 - IN CANADA 02/2003 17X8-EI07

SPECT RA SERIES 72.7 BELL OUTPUT CONNECTIONThe BELL+ and BELL- terminals power bells, sirens and other warning devices requiring a steady voltage ou