26 REFERENCE & INSTALLATION MANUAL
6.12 BELL SQUAWK ON ARM/DISARM WITH REMOTE CONTROL
Section [131 ]: Arming/Disar min g Options
Option [3] OFF = Bell Squawk on Arm/Disarm with Remote Control Disabled (default)
Option [3] ON = Bell Squawk on Arm/Disarm with Remote Control Enabled
When this feature is enabled, the bell or sir en will squawk once upon armi ng with a r em ote control and twice upon
disarming with a remote control. Must be enabled for UL installations.
6.13 NO EXIT DELAY WHEN ARMING WITH REMOTE CONTROL
Section [131 ]: Arming/Disar min g Options
Option [4] OFF = Provides Exit Delay When Arming with a Remote Control (default)
Option [4] ON = No Exit Delay When Arming with a Remote Control
When the option is enabled, the panel cancels the Exit Delay (arms instantly) when a partition is armed with a
remote control. When disabled, the Exit Delay timer will start when a partition is armed with a remote control.
6.14 NO EXIT DELAY BEEPS AND NO BELL SQUAWK WHEN STAY ARMING
Section [131 ]: Arming/Disar min g Options
Option [5] OFF = No Exit Delay Beeps and No Bell Squawk When Stay Arming Disabled (default)
Option [5] ON = No Exit Delay Beeps and No Bell Squawk When Stay Arming Enabled
With this feature enabled, the control panel will prevent the bell or siren from squawking and the keypads from
beeping during the Exit Delay, whenever a partition is Stay Armed.
PART 7: ALARM OPTIONS
7.1 BELL CUT-OFF TIMER (5 minutes minimum for ULC installations)
Section [073] = Partition 1, [074] = Partition 2
000 = Disabled, 001 to 255 minutes, Default = 4 min.
After an audi ble alarm, the bell or siren will stop upon disarmi ng of the partition or when the Bell C ut-Off Timer has
elapsed, whichever comes first.
7.2 RECYCLE ALARM
After the Bell Cut-Off Timer and the Recycle Delay have elapsed, the control panel will re-verify the zone status. If
there are any open zones, the control panel will generate another alarm. In one armed period, the control panel will
repeat this sequence the number of times defined by the Recycle Counter.
7.2.1 RECYCLE ALAR M DELAY
Section [090]
000 = disabled, 001 to 255 minutes, Default = disabled
The Recycle Delay determines the amount of time after Bell Cut-Off that the control panel will wait before
re-verifying zone status.
7.2.2 RECYCLE COU NTE R
Section [091]
000 = disabled, 001 to 255, D efault = disabl ed
The Recycle Counter determines the number of times the control panel will re-verify the zone status after
Bell Cut-Off in one armed period.