8.5.1 Tamper Bypass Options
(Default = enabled) With option [7] enabled in section [3034], the control
panel will ignore the zone’s bypass definition and will follow the option set in
section 8.5 if a tamper or wire fault occurs on a bypassed zone. With option
[7] disabled, Tamper Recognition follows the zone’s bypass definition. This
means that the control panel will not perform any action if a tamper or wire
fault occurs on a bypassed zone.
8.6 K
EYPAD
P
ANIC
O
PTIONS
(Default = disabled) The control panel can generate an alarm (silent or
audible) when two keys are pressed and held simultaneously for 2
seconds. In the section that corresponds to the desired partition, enable or
disable options [1] through [6] as desired:
S
ILENT
A
LARM
The control panel emits a single Confirmation Beep and transmits the
appropriate report code (see section 9.2.10).
A
UDIBLE
A
LARM
The control panel activates the
BELL
output until a user cancels the alarm
with a valid User Access Code or when the Bell Cut-Off Timer elapses (see
section 8.2).
F
IRE
A
LARM
Same as audible operation, except that the bell/siren output will be pulsed
as shown in Figure 5-4 on page 18.
Partition 1: [3123] Partition 3: [3323] Partition 5: [3523] Partition 7: [3723]
Partition 2: [3223] Partition 4: [3423] Partition 6: [3623] Partition 8: [3823]
Option Feature Press and Hold:
[1] Panic 1 Keys [1] and [3]
[2] Panic 2 Keys [4] and [6]
[3] Panic 3 Keys [7] and [9]
Option Alarm Type
[4] Panic 1:
ON
= Audible
OFF
= Silent
[5] Panic 2:
ON
= Audible
OFF
= Silent
[6] Panic 3:
ON
= Fire
OFF
= Silent